-9-
AC charging setting
10A~Rated current.
Regulation step 5A
Boost voltage setting
Battery low voltage
shutdown point setting
Range of adjustment 10-11V
SBU Battery low voltage
power point
SBU Battery high voltage
inverter point
Buzzer switch settings
Range of adjustment 10.5-12.0V
If you choice SBU, when the battery voltage
less than value, the inverter will work in AC
model
Range of adjustment 13V-14.0V
If you choice SBU, when the battery voltage
more than value continue 1min, the inverter
will work in DC model.
The LCD back light on.
13
19
20
Rated current(default)
Range of adjustment 13.8-14.5V
14.1V(default)
17
Floating charging setting
13.5V(default)
10.5V(default)
18
Range of adjustment 13.5-13.7V
11.5V(default)
13.5V(default)
21
LCD ON
LCD OFF(default)
LCD back light settings
Press any button to light up continue 1min.
23
24
Buzzer ON(default)
Buzzer OFF
Save mode switch settings
27
Save off
The save model disenable.
SEN
Sdi(default)
Save mode enable
inverter is set to detect the load every 5/30
seconds
UP
Page up key
DOWN
Page down key
Confirm the exit key
ENTER
Search time settings in
Save mode
28
5s inverter is set to detect the load every 5
seconds.
30s inverter is set to detect the load every
30 seconds.
5s(default)
29
AC charging switch settings
AC charging on(default) AC charging off
Summary of Contents for EP33-1012TLV