Call the AVPro Team at –North America 877-886-5112 Interna1-605-274-6055
a.
Press OK Button to select/enable
b.
Use up/down arrows to enter horizontal pixel location (ex in 720P format set to
712)
c.
Use left/right arrows to enter vertical pixel location (ex. In 720P format set to
1276)
d.
Press OK
e.
RGB Triplet Value will be displayed R:008 G:008 B:008 – in an 8-bit system this
would be almost black (Black RGB are all 0 and White RGB all 255).
3.
Signal Monitor
– This is an abbreviated test for signal loss and frame to frame difference
in an HDMI distribution system. This can be used to diagnose intermittent issues in a
system caused by defective sink, source or repeater and their handling of HDMI and
HDCP handshake and key exchange. This can also be used to identify external devices
causing interruption to the signal – ex. EMI (Electro-Magnetic Interference) from an
HVAC transformer in a commercial facility the “interferes” with the HDMI distribution
system and cause loss of HPD or 5V. The Signal Monitor, when placed in the system will
record the exact minute or second when the error occurred. The Signal Monitor can
record information for up to a year (361 days and 6 hours), collecting actionable
information for diagnosing component or external problems in the system.