PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT
CLEAN, BAGGED AND UNDAMAGED PRIOR
TO INSTALLATION.
2. Pull on the fitted Tubing to ensure it is secure.
Tube should not come free from the Fitting. Water
test the connection assembly prior to leaving the
site to ensure there are no leaks.
DISCONNECTING THE TUBE:
Before disconnecting the Tube from the Fitting,
ensure that the water line is depressurized. Push
Collet square towards the Push-In Fitting Body and
hold. While holding the Collet in, pull on the PE
Tubing to remove from the Push-In Fitting.
TO CUT TUBE:
Cut to fit length of 1/4” Polyethylene (PE) Tubing
and remove any burrs or sharp edges. Ensure
that the outside diameter is free from score
marks. Tube ends should be square.
INSERTING THE TUBE:
1. Firmly and fully insert the Tubing End into the
Push-In Fitting up to the Tube Stop located
approximately 1/2” deep.
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
Please visit
www.murdockmfg.com
for most current specifications.
7109-602-001
Revised: 11/27/17
Page 4 of 11
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Outdoor Bottle Fillers
COLLET
COLLET
O-RING
O-RING
TUBE STOP
COLLET
COLLET
COLLET