background image

PRIOR TO INSTALLATION

:

1. Read all installation instructions carefully, before proceeding.
2. Carefully remove fixture from packaging, preventing scratching or damage.
3. Unit is provided with six (6) AA Alkaline Batteries.
4. Provide mounting surface, sufficient to support the fixture and loads on the fixture. Provide 30” square x 6” 

deep minimum concrete slab, provided by others to securely anchor fixture.

5. Provide rough-ins as shown on the roughing-in and dimensional drawing, including Water Supply, Drain Pipe 

and Gravel Drain Well. (See page 2 for rough-in details)

6. Completely flush water supply lines of all foreign debris, before connecting to the fixture.

INSTALLATION: (see drainage & mounting roughing-in pg2)

1. Locate the unit over rough-ins on the Mounting Pad, mark mounting holes in base flange.
2. Tilt the unit down on its side, next to the mounting location. Install 1/2”-13 Drop-In Anchors. Optional -IAP (In-

Ground Anchor Plate) which is cast into the concrete, is available.

3. Feed the 7/8” OD Flexible Drain Tube into the open ended Drain Tube. Connect the 1/2” Male NPT Fitting to a 

potable water supply. Then tilt the unit into place, making sure that the Tubing is not pinched or kinked. Secure 
the Base Flange to the Mounting Pad with provided hardware.

4. Connect the Battery Pack to matching Battery Wire Terminals. When connected the unit is active.
5. Test for leaks and proper operation, and then install the Access Panel.

START UP:

Air within the Bottle Filler System or the structure supply piping will cause an irregular spout outlet stream until 
purged out by incoming water. Press and hold Pushbutton until steady water stream is achieved.

OPERATION INSTRUCTIONS:

Hand operation:

 Hold container to be filled just below the Filler Tube in the center of the unit, then push 

Pushbutton. When the container is almost filled, release the Pushbutton.

Sensor Operation:

 Hold container to be filled just below the Sensor in the center of the Filler Spout and then 

move the container upward and water flow will start automatically. When the container is almost filled, lower the 
container below the Sensor until the water stops flowing (see label on the Bottle Filler).

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

Outdoor Bottle Fillers

 

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Please visit

 www.murdockmfg.com

 

for most current specifications.

7109-602-001

Revised: 11/27/17

Page 3 of 11

Fill Spout

Sensor

Aluminum Name Plate

Drain

Pushbutton

Summary of Contents for M-OBF4

Page 1: ...nstitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each uni...

Page 2: ...m for most current specifications 7109 602 001 Revised 11 27 17 Page 2 of 11 521 4 1327 363 4 933 23 4 70 ACCESS PANEL GENERAL DIMENSIONS 1 ALL DIMENSIONS ARE IN INCHES MM 2 STOP VALVE NOT PROVIDED 113 8 289 A 7 178 TYP 31 2 89 TYP 11 2 38 MIN GRAVEL DRAIN WELL 3 CUBIC FEET MIN RECOMMENDED Ø12 305 D C B 23 8 60 D C B Ø5 8 4 MOUNTING HOLES IN BASE FLANGE 1 1 2 NOMINAL DRAIN PIPE OPEN AT BOTH ENDS B...

Page 3: ... kinked Secure the Base Flange to the Mounting Pad with provided hardware 4 Connect the Battery Pack to matching Battery Wire Terminals When connected the unit is active 5 Test for leaks and proper operation and then install the Access Panel START UP Air within the Bottle Filler System or the structure supply piping will cause an irregular spout outlet stream until purged out by incoming water Pre...

Page 4: ...m the Push In Fitting TO CUT TUBE Cut to fit length of 1 4 Polyethylene PE Tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the Tubing End into the Push In Fitting up to the Tube Stop located approximately 1 2 deep MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 US...

Page 5: ...is debris or scale in center or two holes in convolution of the water diaphragm Remove and clean CLEANING MAINTENANCE GUIDE For Powder coated units Units should be cleaned using a mild soap solution with a sponge or cotton cloth Wipe down surfaces then rinse with clean water For Stainless steel units 1 To Remove water spots or rust spots stainless steel cleaner polish on a cloth is recommended 2 I...

Page 6: ... Remove six 6 Screws that holds the Bottom Access Panel to the unit this allows access to the Filter 2 Pull the Filter Assembly straight up about six 6 inches and then turn the Small Valve on the Filter Inlet a 1 4 turn to shut off the water supply to the Filter 3 While holding the Filter Assembly up about six 6 inches unscrew the lower Filter Cartridge from the top of the Filter Assembly Then mov...

Page 7: ... Pack back in the Metal Box and test for proper operation Then re install the Access Panel WIRING DIAGRAM BATTERY PACK SOLENOID SENSOR RED WIRES MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications 7109 602 001 Revised 11 27 17 Page 7 of 11 I N ...

Page 8: ...or Bottle Fillers MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications 7109 602 001 Revised 11 27 17 Page 8 of 11 SENSOR DETAIL SO ONLY 30 31 32 33 34 1 2 3 4 19 5 16 18 20 21 22 23 27 25 24 26 6 9 14 7 10 11 15 12 13 7 17 8 7 28 29 9 35 42 ...

Page 9: ...6 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications 7109 602 001 Revised 11 27 17 Page 9 of 11 I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S Outdoor Bottle Fillers SENSOR DETAIL SO ONLY 30 31 32 33 34 1 2 3 4 19 5 16 18 20 21 22 23 27 25 24 26 6 9 14 7 10 11 15 12 13 7 17 8 7 28 29 9 40 39 38 1 36 3 2 35 37 ...

Page 10: ... N S T R U C T I O N S Outdoor Bottle Fillers MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications 7109 602 001 Revised 11 27 17 Page 10 of 11 1 2 3 4 19 5 16 18 20 21 22 23 25 24 6 9 14 7 10 11 15 12 13 7 17 8 7 9 12 42 35 ...

Page 11: ...23 000 1 4 x 3 8 O D TUBE UNION PUSH IN 22 1895 005 000 3 8 O D TUBE x 1 2 NPT MALE CONNECTER 23 2170 002 500 3 8 O D LOW DENSITY PE TUBING x 2 5 24 0112 011 000 10 32 x 3 8 CENTER REJECT SCREW 25 2570 101 001 REPLACEMENT NON METERING AIR TROL VALVE 26 2570 130 001 9 12 VDC SOLENOID OP VALVE ASSEMBLY 27 7013 046 001 6 AA BATTERY PACK 28 0302 003 000 8 32 HEX NUT 29 6527 108 000 8 INTERNAL TOOTH LO...

Reviews: