INSTALLATION:

1.   

Provide rough-ins as shown in Roughing-In and Dimensional Drawing.

2.   

Anchor water cooler to wall through anchor clips on the bottom of the base.

7.   Assemble bottom cover to water cooler with screws furnished. 

2.   Air within the water cooler system or the structure supply piping will cause an irregular bubbler outlet stream 

until purged out by incoming water. Covering the bubbler with a clean cup (or similar object) is recommended 
when first activating water cooler to prevent excessive splashing. Depress the pushbutton until steady water 
stream is achieved.

6.   Plug water cooler in to electrical outlet and make sure unit begins to function.

START UP:

1.   Before connecting power supply and assembling bottom cover to water cooler, but after thoroughly flushing 

the supply line and connecting it to the fixture, turn on building water supply and check all connections for 
leaks.

4.   Recheck all water and drain connections with water flowing through system.

5.   With power still NOT connected, carefully manually rotate cooling fan to insure proper clearance and free fan 

action.

3.   If water flow requires adjustment, insert a slotted narrow blade screwdriver through the hole centered on the 

pushbutton to the flow regulator. Turning clockwise will increase flow and turning counterclockwise will 
decrease flow.

4.   After thoroughly flushing the 3/8” O.D. supply line, connect water supply to water cooler.

5.   Make up 1-1/4” O.D. P-Trap waste connection.

3.   

Remove the front panel from the water cooler by taking out the screws on each side at the bottom front, press 

the panel sides together at the bottom so that front panel clips disengage from the housing sides and carefully 
pull forward and down. Set panel aside in a safe place where it will not be damaged.

 

A511.5

Page 3 of 9

RVA 

05/28/21

7020-921-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

Summary of Contents for A511.5 Series

Page 1: ... into the water cooler or drinking fountain or Murdock s limited warranty is void LIMITED WARRANTY UNITED STATES CANADA LIMITED EXPORT WARRANTY One year on parts only Murdock warrants that every cooler bottle filling station packaged water chiller fountain and accessory to be free from defects in material and workmanship under normal use for one 1 year from date of install or eighteen 18 months af...

Page 2: ...rnished with this water cooler to meet this requirement ROUGHING IN AND DIMENSIONAL DRAWING Prior to roughing consult with local state and federal codes for proper mounting height A511 5 Page 2 of 9 RVA 05 28 21 7020 921 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of GENERAL NOTES 1 ALL DIMENSIONS ...

Page 3: ...ns with water flowing through system 5 With power still NOT connected carefully manually rotate cooling fan to insure proper clearance and free fan action 3 If water flow requires adjustment insert a slotted narrow blade screwdriver through the hole centered on the pushbutton to the flow regulator Turning clockwise will increase flow and turning counterclockwise will decrease flow 4 After thorough...

Page 4: ...hould any of these problems arise from the water supply 5 Do NOT solder copper tube when inserted into the coupler as damage to the o ring will result IMPORTANT 8 This unit must be grounded per the requirements of applicable electrical codes 9 Warranty is voided if installation is not made following current Acorn Engineering installation instructions and if components are assembled to the fixture ...

Page 5: ...f the overload protector b Check the incoming voltage to make sure it is within 10 of the serial nameplate rating c A restriction or moisture in the system will also cause intermittent cycling A certified refrigeration mechanic should be contacted in this situation d Change the overload or relay if defective 5 Noisy Operation a Check to make sure the fan blade is rotating freely b Make sure the wa...

Page 6: ...nless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner CARTRIDGE VALVE PARTS BREAKDOWN STANDARD CARTRIDGE VALVE PARTS BREAKDOWN ITEM PART NUMBER DESCRIPTION 1 7000 050 001 Valve Cartridge Assembly 2 7000 060 000 Valve Cartridge 3 7000 053 199 Jam Nut ITEM PART NUMBER DESCRIPTION 1 2 3 7000 000 001 7000 060 001 0401 0...

Page 7: ...the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET...

Page 8: ...octor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 4 5 6 12 13 14 17 18 19 9 20 22 9 15 7 2 11 10 16 8 3 21 23 1 24 25 15 26 24 25 18 NOTE Flow Restrictor Only Available With Low Flow Bubbler CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS ...

Page 9: ... 000 START CAPACITOR 220V 7012 014 001 COMPRESSOR 7012 030 001 COMPRESSOR 220V 6 7003 350 000 FAN BLADE 7003 302 000 FAN MOTOR 7012 062 001 FAN MOTOR 220V 8 7000 021 001 Y STRAINER 7004 009 020 SIDE PANEL GRAY 7004 081 199 SIDE PANEL STAINLESS STEEL 10 7004 024 199 BACK PLATE 11 0124 056 000 8 x 3 8 LONG PHILLIP PH SHEET METAL SCREW 12 7000 039 001 DRAIN TUBE ASSEMBLY 13 7000 005 199 DRAIN ADAPTER...

Reviews: