CLEANING & MAINTENANCE GUIDE:
     

1.   Motors have lifetime lubrication and do not require scheduled maintenance. 

     2.   Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it will
           cycle on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air hose or brush 
           the condenser fins and cabinet ventilation louvers. In environments where dirt and dust is more prevalent, clean more
           frequently. 
     3.   Periodically remove access panels and clean out in-line strainer. 
     4.   Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the Murdock warranty. 
     5.   Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra care must be used 
           cleaning chrome plated items and mirror finished stainless steel. They can scratch easily and should only be cleaned 
           using a clean, soft cloth and mild soap with water or a mild glass cleaner. 

CARTRIDGE VALVE PARTS BREAKDOWN

STANDARD CARTRIDGE VALVE PARTS BREAKDOWN

 

 

ITEM # 

PART NUMBER 

DESCRIPTION 

7000-050-001 

           Valve Cartridge Assembly

 

7000-060-000 

           Valve Cartridge 

7000-053-199 

Jam  Nut

 

 

ITEM #

PART NUMBER

DESCRIPTION

1

2

3

7000-000-001

7000-060-001

0401-015-000

Pushbutton Bubbler Assembly

Valve Cartridge

O-Ring

4

7000-008-199

Bubbler Adapter

5

7000-003-000

Bubbler Washer

 

Repairs must be made with Acorn Engineering parts only. 
Please order through your local representative or distributor.
The phone number to locate your local representative is 
1.800.591.9360.

 

 

A511.5

Page 6 of 9

RVA 

05/28/21

7020-921-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

Summary of Contents for A511.5 Series

Page 1: ... into the water cooler or drinking fountain or Murdock s limited warranty is void LIMITED WARRANTY UNITED STATES CANADA LIMITED EXPORT WARRANTY One year on parts only Murdock warrants that every cooler bottle filling station packaged water chiller fountain and accessory to be free from defects in material and workmanship under normal use for one 1 year from date of install or eighteen 18 months af...

Page 2: ...rnished with this water cooler to meet this requirement ROUGHING IN AND DIMENSIONAL DRAWING Prior to roughing consult with local state and federal codes for proper mounting height A511 5 Page 2 of 9 RVA 05 28 21 7020 921 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of GENERAL NOTES 1 ALL DIMENSIONS ...

Page 3: ...ns with water flowing through system 5 With power still NOT connected carefully manually rotate cooling fan to insure proper clearance and free fan action 3 If water flow requires adjustment insert a slotted narrow blade screwdriver through the hole centered on the pushbutton to the flow regulator Turning clockwise will increase flow and turning counterclockwise will decrease flow 4 After thorough...

Page 4: ...hould any of these problems arise from the water supply 5 Do NOT solder copper tube when inserted into the coupler as damage to the o ring will result IMPORTANT 8 This unit must be grounded per the requirements of applicable electrical codes 9 Warranty is voided if installation is not made following current Acorn Engineering installation instructions and if components are assembled to the fixture ...

Page 5: ...f the overload protector b Check the incoming voltage to make sure it is within 10 of the serial nameplate rating c A restriction or moisture in the system will also cause intermittent cycling A certified refrigeration mechanic should be contacted in this situation d Change the overload or relay if defective 5 Noisy Operation a Check to make sure the fan blade is rotating freely b Make sure the wa...

Page 6: ...nless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner CARTRIDGE VALVE PARTS BREAKDOWN STANDARD CARTRIDGE VALVE PARTS BREAKDOWN ITEM PART NUMBER DESCRIPTION 1 7000 050 001 Valve Cartridge Assembly 2 7000 060 000 Valve Cartridge 3 7000 053 199 Jam Nut ITEM PART NUMBER DESCRIPTION 1 2 3 7000 000 001 7000 060 001 0401 0...

Page 7: ...the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET...

Page 8: ...octor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 4 5 6 12 13 14 17 18 19 9 20 22 9 15 7 2 11 10 16 8 3 21 23 1 24 25 15 26 24 25 18 NOTE Flow Restrictor Only Available With Low Flow Bubbler CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS ...

Page 9: ... 000 START CAPACITOR 220V 7012 014 001 COMPRESSOR 7012 030 001 COMPRESSOR 220V 6 7003 350 000 FAN BLADE 7003 302 000 FAN MOTOR 7012 062 001 FAN MOTOR 220V 8 7000 021 001 Y STRAINER 7004 009 020 SIDE PANEL GRAY 7004 081 199 SIDE PANEL STAINLESS STEEL 10 7004 024 199 BACK PLATE 11 0124 056 000 8 x 3 8 LONG PHILLIP PH SHEET METAL SCREW 12 7000 039 001 DRAIN TUBE ASSEMBLY 13 7000 005 199 DRAIN ADAPTER...