IMPORTANT
This fixture is intended to dispense water that has been lowered in temperature, but otherwise remains
unchanged by the materials in the water cooler. It is common for electrical equipment to be grounded to
water lines either within a structure or away from it. Every attempt should be made to prevent this kind
of grounding from generating electrical feedback into the water cooler creating electrolysis. Electrolysis
will cause a metallic taste or cause water metal content to increase.
NOTICE
A dielectric coupling must be used to connect the water cooler to the water supply . A nonmetallic
strainer is furnished with this water cooler to meet this requirement.
ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper mounting height.
A511.5
Page 2 of 9
RVA
05/28/21
7020-921-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MM]
2. ALLOW 4 INCHES [102 MM] MINIMUM CLEARANCE PER SIDE FOR VENTILATION
3. STOP VALVE, TRAP, & ELECTRICAL OUTLET NOT SUPPLIED
AIR FLOW
18
1
4
"
ELECTRIC
OUTLET
2
1
2
"
2"
33
1
2
"
12
1
2
"
3
7
8
"
6"
12"
1"
28
3
4
"
41
3
8
"
ORIFICE
HEIGHT
Ø1
1
4
WASTE
3
8
OD
COPPER TUBE
SUPPLY
1
1
4
TRAP
(NOT FURNISHED)
32
1
2
"
TAILPIECE
1
3
8
"
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S