![Murata DNT90M Series Integration Manual Download Page 61](http://html1.mh-extra.com/html/murata/dnt90m-series/dnt90m-series_integration-manual_1857330061.webp)
Figure 8.6.1.7
Figure 8.6.1.7 shows the
I/O Parameters
tab contents, corresponding to Bank 5. All GPIO ports are configured as inputs.
The 12-bit ADC input readings and DAC output settings are given in
Big-Endian
byte order. Event flags are presented on
the right side of the window.
Figure 8.6.1.8
Figure 8.6.1.8 shows the first
I/O Settings
tab contents, corresponding to Bank 6 GPIO configurations other than alternate
GPIO functions. This tab allows the direction of the GPIO ports to be set both for active and sleep modes, and in the case
of GPIO outputs, the initial power up states and sleep mode states to be set. When GPIO ports 0 - 3 are configured as
inputs, event interrupts can be set for them with check boxes. The type of interrupt trigger is selected from the drop-down
boxes to the right of the check boxes. Periodic I/O reporting, reporting interval and enable/disable sleep I/O states and I/O
binding can also be configured under this tab.
©2012 by Murata Electronics N.A., Inc.
DNT90M Integration Guide (2012/09/17)
Page 61 of 74
www.murata.com