![Murata DNT90M Series Integration Manual Download Page 58](http://html1.mh-extra.com/html/murata/dnt90m-series/dnt90m-series_integration-manual_1857330058.webp)
Returning to the
I/O Tools
tab, the multi-tab
Configuration
window for each radio can be accessed by clicking on its
Config
button. The data presented on the first six tabs corresponds to configuration register Banks 0 through 5 as discussed in
Section 4.2 above, with the data on the next two tabs corresponding to configuration register Bank 6.
Figure 8.6.1.2
The
Transceiver Setup
Tab is shown in Figure 8.6.1.2 and corresponds to Bank 0. The current values of each Bank 0
parameter are displayed and can be updated by selecting from the drop-down menus or entering data from the keyboard,
and then pressing the
Apply Changes
button. Note that data is
displayed and entered in Big-Endian order
. The utility
program automatically reorders multi-byte data to and from Little-Endian order when building or interpreting messages.
©2012 by Murata Electronics N.A., Inc.
DNT90M Integration Guide (2012/09/17)
Page 58 of 74