![Murata DNT90M Series Integration Manual Download Page 34](http://html1.mh-extra.com/html/murata/dnt90m-series/dnt90m-series_integration-manual_1857330034.webp)
Announce/Error
message format details are shown in Tables 7.3.18 through 7.3.19:
Startup Announcement or Error Code
Byte Offset
Field
Description
0x00
Start-of-Packet
0xFB = Indicates start of protocol formatted message
0x01
Length
0x02 = Number of bytes in message following this byte
0x02
Packet Type
0x27 = Indicates this is an Announce/Error message
0x03
Announce Status
0xA0 = Startup initialization complete
0xE1 = Invalid argument
0xE4 = Register read only error
0xEC = Brownout reset
0xED = Watchdog reset
0xEE = Hardware Error (Crystal or Radio Error)
Table 7.3.18
Heartbeat Announcement
Byte Offset
Field
Description
0x00
Start-of-Packet
0xFB = Indicates start of protocol formatted message
0x01
Length
0x07 = number of bytes in message following this byte
0x02
Packet Type
0x27 = Indicates this is an Announce/Error message
0x03
Announce Status
0xA8 = Heartbeat message
0x04 - 0x06
Originator MAC Address
MAC address of originator, in Little Endian byte order
0x07
RSSI
Received power in dBm, -128 to 126, 127 if invalid
0x08
Beacon RX Power
Average beacon RX power in dBm, uses 0.0625 “alpha” averaging filter,
-128 to 126 or 127 if invalid
Table 7.3.19
©2012 by Murata Electronics N.A., Inc.
DNT90M Integration Guide (2012/09/17)
Page 34 of 74
www.murata.com