![Muonio SE1 Manual Download Page 3](http://html1.mh-extra.com/html/muonio/se1/se1_manual_1857012003.webp)
This product must be installed by a fully qualified, competent person, and
installation must comply with the guidance, standards and regulations
applicable to the country or state where the product is being installed. Failure
to comply with the requirements of the relevant guidance, standards and
regulations could lead to injury, death or prosecution.
Always isolate the AC mains supply before installing or working on any
components that require 230 V~, 50 Hz supply.
TECHNICAL INFORMATION
SE1 SMART ENERGY SWITCH
TERMINALS
0.5 mm
2
to 1.5 mm
2
DIMENSIONS
350 x 92 x 57 mm
MOUNTABLE
DIN rail or screws
WEIGHT
700 g
FUSED POWER SUPPLY
230 V ~, 50 Hz, Single Phase
5 Amp including separate 3 Amp fuse for the boiler
0.5 Amp for the logic part
All fuses are medium burn type
DESCRIPTION
5 control points/relays with power outlets for controlling various points/appliances
Hot water controls dedicated to relay No.2
Relay No.1 is for boiler control but can be programmed for other purposes
Optional domestic hot water sensor connector
Auxiliary (NO) Call for Boiler Relay 1
Relay 1 is a volt free outlet, Relays 2-5 are executed as power outlets
LED indication for each control point/relay
Relay 2-5 each have 3 parallel power outputs
Ground/Earth Terminal Points
Easy ‘Push-Open’ Connections
WIRELESS FREQUENCY
2.4 GHz with external antenna option
ENCLOSURE RATING
IP20
TRANSIENT SUPPRESSION
Yes
DEFROST SUPPORT Yes
CONTENT IN THE BOX
SE1 device, DHW sensor, manual, external antenna
HARDWARE VERSION
1.0