Wiring examples - W plan heating
W PLAN HEATING
This scheme uses a 3 port diverter valve, which has only 2 settings - heating only or hot water only. The valve is
in position A by default, which is for hot water. The valve moves to position B (Heating) when power is applied.
FIGURE 30. W PLAN HEATING
DIVERTER VALVE
BOILER
DHW TANK
* SENSOR
FIGURE 31. W PLAN HEATING WIRING EXAMPLE
In this system, there is one heating zone and one DHW zone with a DHW sensor. The Brown wire on the valve is
connected to NC on Relay 2. This means that the Brown wire is live whenever there is not a call for hot water. If
there is a call for hot water, the Brown wire will be disengaged and the valve moves to its default position which is
hot water priority. When there is a need for DHW the boiler is called through the bridge from SL to AUX_L.
RADIATOR RADIATOR
Connect DHW
sensor (*) here
Blue (Neutral)
Green/Yellow (Earth)
Brown (Live)
volt free to Boiler
RELAY 1
BOILER
RELAY 2
RELAY 3
RELAY 4
RELAY 5
MANUAL RELAY SWITCH:
1) RELAY 1
2) RELAY 2
3) RELAY 3
4) RELAY 4
5) RELAY 5
6) MANUAL
SWITCH
ENABLE
12 34 56
ON
OFF
N
N_out
T- L
L_out
MAIN
INPUT
L
N
F1:0.5A
F2:6.3A
EARTHING
EARTHING
EARTHING
RELAY OUT
VOLT FREE
BOILER RELAY
VOLT FREE ONLY INPUT!
+ DIG. -
DIGITAL
12
3
45
7c 6d
8
RESERVED FOR
DOMESTIC
HOT WATER
3N X
3
ID KE
Y
N_outL
_out N_outL
_out
DHW TEMPERAT
URE
PROBE
AUX BOILER
CALL NO
(RELAY 1)
N
BOILER
POWER
SUPPLY
BOILER
FUSE
F3:3A
L
10 10a
6a 7a 6b 7b 6c
7d
Aux- L
NC
T- SL
SL
SL
G
GG
GG
G
POWER OK
DEFROST
SL
SYS
TE
M
1
BLI
NK
SYSTE
M
2
3L
X
3
4L
X
3
4N X
3
5N X
3
5L
X
3
NC
11
ANTENNA CONNEC
TO
R
9