© Munters AB, 2013
26
fig.21
To reset the correct tension:
•
open the safety mesh guards;
•
unscrew motor slide fixing screws (without
removing them);
•
using the tensioning belt adjuster instruction
tighten the V-belt by pushing the motor sideways;
•
tighten the fixing screws adequately;
•
fix the safety meshes guard to the fan housing.
8.4 Tensioning belt adjuster
1. Be sure to adjust the two M6 nuts and the grub screw, in order to
avoid any clearance of it.
fig.22
2. Tighten the two bolts in the motor plate so that the V-belt remains
in tension.
Maintenance
Chapter8
Do not operate the fan with the safety protections removed: safety meshes can be
removed only with specific tools by qualified technicians when the fan reaches a
complete standstill.
The fixing sytems of the safety protections are not interchangeable with other
devices. Therefore, if for maintenance reasons the user damages or loses any
component, this must be definetely ordered from the manufacturer as spare parts
and it cannot just be replaced with other components, even similar, not supplied
by the manufacturer itself. In this particular event the manufacturer refuses all
responsibility on consequent damages caused to things and people and considers
any kind of warranty lost.
Warning