Each CSI24 Inlet system that is 30'L. or longer consists of (1) Left Door, (1 or more) Middle Doors and
(1) Right Door. The number of Middle Doors depends on the length of the run of CSI24 Doors. For example,
if the run of CSI24 Doors is 40'L. then there is (1) Left Door, (2) Middle Doors and (1) Right Door. If the run
is 100'L. then there is (1) Left Door, (8) Middle Doors and (1) Right Door. In the next steps all the doors will
be assembled before installing them to the framed openings.
See Figure 3.
If the run is only 20'L. then there
is only the Left Door and the Right Door.
Figure 3
View from Hallway/Hinge Side
TEK Screw [H]
TEK Screw [H] location
for Left End Door
Door Edge Trim [2]
Figure 4
Do not use
this hole at
this time.
2.3 Door Assembly
Step 5
Slide Door Edge Trim [2] onto the bottom edge of the CSI24 Door [1] and secure it with (14) TEK Screws [H]
through the (6) single holes in the middle area of the Door Edge Trim and the left most hole.
See Figure 4.
Middle Door
Right Door
Left Door
2.4 Left Door Assembly
NOTE:
The Left and Right ends of the system are
determined from the Hallway/Actuator side of
the inlet, with the inlet mounted in the room.
CSI24 Door with Hinge [1]