Summary of Contents for S228668-20

Page 1: ...MANUAL NO 229172 11 1 2022 OWNER S MANUAL 20 25 HP LO SPEED HEAVY DUTY 20 50 HP HIGH SPEED TRANSITION FOR AERATION FLOOR ...

Page 2: ...he system If you have any further questions comments improvements or suggestions regarding the contents of any of the manuals provided please see the contact information below This machine is covered by one or more United States patents Refer to www siouxsteel com for current patent information Or scan this QR Code to go directly to the patent area on the website ALL safety decals are no charge fr...

Page 3: ...ntents 1 Part Numbers 1 2 Safety Information 2 2 1 Safety Alert Symbols 3 3 Transition Assembly Instructions 7 4 Fan Transition Parts Diagrams 8 5 Fan Transition Configurations 10 New Product Warranty 11 ...

Page 4: ...mbers S228668 20 20HP Lo Speed Heavy S228668 20HS 20HP Hi Speed S228668 25 25HP Lo Speed Heavy S228668 30HS 30HP Hi Speed S228668 40HS 40HP Hi Speed S228668 50HS 50 HP Hi Speed S228668S Transition with Blank Panel ...

Page 5: ... your responsibility as owner operator to know what requirements hazards and precautions exist and to inform all personnel associated with the equipment Any alterations to equipment are strictly forbidden Such alterations may result in serious injury or death and will void any warranty on product This equipment shall be installed in accordance with the current installation codes and applicable reg...

Page 6: ...o unauthorized modifications to equipment Modifications may endanger function and or safety of the unit Periodically check all mechanical and electrical components Keep unit in good working condition PRACTICE SAFE MAINTENANCE Read and understand correct service procedures before operating Keep area clean and dry to prevent accidents Machine should never be lubricated serviced or adjusted while it ...

Page 7: ...LL PROTECTION Appropriate fall protection should be worn when working at elevations greater than six 6 feet Signal Word Color Potential Injury or Damage Likelihood of Occurrence DANGER Red Severe Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WILL Occur if Warning is ignored WARNING Orange Severe Indicates a hazardous situation which if not ...

Page 8: ...s in accordance with all applicable codes and standards including fire rated construction WARNING To prevent explosion or fire 1 Carefully review the operator s manual 2 Clean under floor as fines may cause a bin fire 3 Do not use to exhaust hazardous or explosive material and vapors 4 Disconnect and lock out all power sources before servicing equipment WARNING Keep clear of all moving parts 1 Kee...

Page 9: ...ain may trap and suffocate If you enter a bin of flowing grain you can be completely submerged in grain in seconds Failure to heed may cause serious injury or death WARNING Heater must be electrically interlocked with fan Never operate heater without airflow Failure to do so may cause serious injury or death CAUTION To avoid personal injury frequently inspect all mechanical and electrical componen...

Page 10: ...ing far enough to secure wall brackets 18 19 to transition and outside of bin Secure wall brackets to transition with 5 16 x bin bolts 36 2 and 5 16 flange nuts 36 4 Cut 2 pieces of foam 16 to 16 length and attach to outside of bin Slide wall brackets against the bin side wall sheet over foam see detail 2 Note duct supports 15 must be aligned so that the bin sheet lies in the center of the support...

Page 11: ...8 16 4 Fan Transition Parts Diagrams 16 ...

Page 12: ...ANSITION ALT SIDE 20 50HP 1 27 228678 PANEL TRANSITION FAN 20HP 1750RPM CENTRFGL 1 228679 PANEL TRANSITION FAN 25HP 1750RPM CENTRFGL 228680 PANEL TRANSITION FAN 20HP 3500RPM CENTRIFGL 228681 PANEL TRANSITION FAN 30HP 3500RPM CENTRFGL 228682 PANEL TRANSITION FAN 40HP 3500RPM CENTRFGL 228683 PANEL TRANSITION FAN 50HP 3500RPM CENTRFGL 228677 BLANK PANEL FOR MOUNTING OTHER FANS 30 228686 HDW TRANS 20 ...

Page 13: ...rete pad is not used an angle iron frame may be constructed for the fan to rest on providing it is strong enough to support the fan s weight Two support cables should also be used in conjunction with the angle iron frame running from the top portion of the fan to the adjacent bin wall stiffeners See fan manual for further details REF CENTRIFUGAL FAN REF CENTRIFUGAL TRANSITION PANEL ...

Page 14: ...ors Cage and Ladder Systems Catwalks and Towers Grain Dryers and Peak Walk Arounds 1 Year New Daay Paddle Bin Sweep 1 Year Daay Power Sweep 1 Year DSH System 1 Year Exclusions specific to Grain Bins Damage or loss of any kind from 1 excessive vacuum or internal pressure from the operation of fans in an empty grain bin and from the blockage of air passages for any reason including but not limited t...

Page 15: ...OR TO MODIFY THE TERMS OR LIMITATIONS OF THIS WARRANTY IN ANY WAY G GOVERNING LAW VENUE These warranties and all terms set forth herein are governed by the laws of the State of South Dakota and where applicable the laws of the United States of America Any and all disputes arising from these warranties the purchase and use of the Products bodily injury and property damage claims or otherwise must b...