maintenance of motor
˖
0 1 2
F
3
E
4
D
5
C
6
B
7
A
89
Installation manual
18
High pressure duct
Table.12-1
ENC1
POWER_S
00 11 22
FF
33
EE
44
DD
55
CC
6 6
B B
7 7
A A
8 899
Mainboard codes indication label
Fig.12-1
Horsepower code
ENC1(system A) Toggle switch
Code
7
Capacity(Horsepower)
11200W(4.0HP)
12500W(5.0HP)
14000W(5.0HP)
For set horsepower
Note: The horsepower
has been set before
leaving the factory,
anyone can’t
modify it except the
maintenance person.
A
6
5
4
3
2
1
0
8
9
2200W(0.8HP)
2800W(1.0HP)
3600W(1.2HP)
4500W(1.5HP)
5600W(2.0HP)
7100W(2.5HP)
8000W(3.0HP)
9000W(3.2HP)
10000W(4.0HP)
16000W(6.0HP)
NOTE
200 (8.0HP): Please dial switch ENC1 to B for system A
and 8 for system B.
250 (9.0HP): Please dial switch ENC1 to C for system A
and 9 for system B.
280 (10.0HP): Please dial switch ENC1 to D for system A
and 9 for system B.
ENC1 is used for setting the refrigeration capacity(refer to
Table.12-1 for different indoor unit) of the indoor unit.
For 71/80/90/112/140/160 models
Static Pressure set
ENC2
Static_Pressure
00 11 22
FF
33
EE
44
DD
55
CC
6 6
B B
7 7
A A
8 899
Fig.12-2
ENC2 is used for setting the static pressure (refer to
Table.12-2 for different indoor unit) of the indoor unit.
0
1
7.1kw 8.0kw 9.0kw 11.2kw 14kw 16kw 20kw 25kw 28kw
0
~
20Pa
21
~
80Pa
40
~
60Pa
The static pressure in below table is the optimal static pressure
range which means the airflow, noise, and dehumidification are
all in the best state.
●
81
~
120Pa
121
~
170Pa
171
~
200Pa
61
~
120Pa
121
~
170Pa
171
~
200Pa
\
2
3
4
ENC2
Table.12-2
6:
definition
00 means shutting down the
10 means shutting down the
11 means shutting down the
unit to “stop cold air” at 15
01 means shutting down the
unit to “stop cold air” at 20
unit to “stop cold air” at 24
unit to “stop cold air” at 26
(by default)
6:
definition
00 means the time of stopping
TERMAL fan is 4 minutes
01 means the time of stopping
TERMAL fan is 8 minutes
10 means the time of stopping
TERMAL fan is 12 minutes
11 means the time of stopping
TERMAL fan is 16 minutes
(by default)
If the outdoor unit has Auto-address function is not necessary to
set manually the indoor unit address.
If the outdoor unit does not have the Auto-address function or if
you want to set the address manually, it should be done by
remote control (wireless or wired). In models 200, 250 and 280
must be set two addresses, one on each control board. To do this,
first connect the infrared receiver to one PCB, assign the first
address and then connect to the other to do the same.
When connecting a centralized control, if all indoor units are
MVD D4+ or MVD DC series, the central control can be
connected directly to terminals XYE of the outdoor unit, you
must activate the Auto-address dip-switch (except 3 pipes system).
Indoor unit address set
Capacity set
Note: To make the addressing you can contact with
Mundoclima after sales service.