PAGE 40 — DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #0 (02/04/14)
Output Terminal Familiarization
The “
Output Terminal Panel
” (Figure 8) is provided with the
following:
■
■
■
■
■
Three (3) 120/240V output receptacles @ 50 amp
■
■
■
■
■
Three (3) Circuit Breakers @ 50 amps
■
■
■
■
■
Two (2) 100V GFCI receptacles @ 20 amp
■
■
■
■
■
Two (2) GFCI Circuit Breakers @ 20 amps
■
■
■
■
■
Five (5) Output Terminal Lugs ( U, V, W, O, Ground)
Output Terminal Panel
The
Output Terminal Panel
(Figure 9) shown below is located
on the right-hand side (left from control panel) of the generator.
Lift up on the cover to gain access to receptacles and terminal
lugs.
Figure 9. Output Terminal Panel
DCA-220SSJ/SSJU — OUTPUT TERMINAL PANEL FAMILIARIZATION
Terminal legs “
O
” and “
Ground
” are considered
bonded
grounds.