DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #0 (02/04/14) — PAGE 11
1
DCA-220SSJ/SSJU — RULES FOR SAFE OPERATION
POWER
CORD
(POWER ON)
WET
HANDS
During operation of this generator, there
exists the possibility of
electrocution,
electrical shock or burn,
which can cause
severe bodily harm
or even
DEATH!
To avoid these hazards:
NEVER
use damaged or worn cables when connecting
equipment to the generator. Make sure power connecting
cables are securely connected to the generator’s output
terminals, insufficient tightening of the terminal connections
may cause damage to the generator
and electrical shock.
NEVER
grab or touch a live power
cord with wet hands.
NEVER
touch output terminals
during operation. This is extremely
dangerous.
ALWAYS
stop the
machine and place the circuit
breaker in the
OFF
position when
contact with the output terminals is
required.
Backfeed to a utility system can
cause
electrocution
and or property
damage.
DO NOT
connect to any
building's electrical system except
through an approved device or after
building main switch is opened.
ALWAYS
have a licensed electrician
perform the installation
DANGER - ELECTROCUTION HAZARDS
Generator Grounding
To guard against electrical shock and possible damage to
the equipment, it is important to provide a good
EARTH
ground.
Article 250 (Grounding) of the
National Electrical Code
(NEC) provides guide lines for proper grounding and specifies
that the cable ground shall be connected to the grounding
system of the building as close to the point of cable entry
as practical.
The following safety recommendations should also be
followed:
■
ALWAYS
make sure generator is properly grounded.
■
NEVER
use gas piping as an electrical ground.
■
ALWAYS
make sure that electrical circuits are properly
grounded
per the
National Electrical Code
(NEC) and
local codes before operating generator. Severe
injury
or
DEATH!
by electrocution can result from operating an
ungrounded generator.
■
ALWAYS
be sure to use the ground terminal (green wire)
when connecting a load to the U,V, and W output
terminal lugs.
Electrical Safety
■
ALWAYS
have a qualified electrician perform the
generator wiring installation.
■
ALWAYS
make sure generator installation is accordance
with the
National Electrical Code
(NEC) and local codes
before operating generator.
■
NEVER
use a defective or frayed power cable. Check
the cable for cuts in the insulation.
■
NEVER
use a extension cord that is frayed or damaged
where the insulation has been cut.
■
ALWAYS
make certain that proper extension cord has
been selected for the job. See Table 6.
■
NEVER
power cables or cords
lay in wate
r.
■
NEVER
stand in water
while AC power from the generator
is being transfer to a load.
Summary of Contents for Power WHISPERWATT DCA-220SSJ
Page 3: ...DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 PAGE 3 1 DCA 220SSJ SSJU NOTE PAGE...
Page 69: ...DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 PAGE 69 1 NOTE PAGE...
Page 92: ...PAGE 92 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU BATTERY ASSY...
Page 94: ...PAGE 94 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU MUFFLER ASSY...
Page 96: ...PAGE 96 DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 DCA220SSJ SSJU FUELTANK ASSY...
Page 113: ...DCA 220SSJ SSJU OPERATION AND PARTS MANUAL REV 0 02 04 14 PAGE 113 1 NOTE PAGE...