background image

 

 

 

Notices

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Copyright  ©  MultiLane  Inc.  All  rights  reserved.  Licensed 
software  products  are  owned  by  MultiLane  Inc.  or  its 
suppliers  and  are  protected  by  United  States  copyright 
laws and international treaty provisions. 
 
Use,  duplication,  or  disclosure  by  the  Government  is 
subject to restrictions as set forth in subparagraph (c)(1)(ii) 
of  the  Rights  in  Technical  Data  and  Computer  Software 
clause  at  DFARS  252.227-7013,  or  subparagraphs  (c)(1) 
and (2) of the Commercial Computer Software -- Restricted 
Rights clause at FAR 52.227-19, as applicable. 
 
MultiLane  Inc.  products  are  covered  by  U.S.  and  foreign 
patents,  issued  and  pending.  Information  in  this 
publication  supersedes  that  in  all  previously  published 
material.  Specifications  and  price  change  privileges 
reserved. 
 

General Safety Summary 

Review  the  following  safety  precautions  to  avoid  injury 
and  prevent  damage  to  this  product  or  any  products 
connected  to  it.  To  avoid  potential  hazards,  use  this 
product only as specified. 
Only  qualified  personnel  should  perform  service 
procedures. 
While  using  this  product,  you  may  need  to  access  other 
parts of the system. Read the General Safety Summary in 
other system manuals for warnings and cautions related to 
operating the system. 
 

 

To Avoid Fire or Personal Injury 
 
Use Proper Power Cord. 

Only use the power cord specified 

for this product and certified for the country of use. 
 

Observe  All  Terminal  Ratings. 

To  avoid  fire  or  shock 

hazard,  observe  all  ratings  and  markings  on  the  product. 
Consult the product manual for further ratings information 
before making connections to the product. 
Do  not  apply  a  potential  to  any  terminal,  including  the 
common terminal that exceeds the maximum rating of that 
terminal. 
 

Do Not Operate Without Covers. 

Do not operate this product with covers or panels removed. 
 

Avoid  Exposed  Circuitry. 

Do  not  touch  exposed 

connections and components when power is present. 
 

Do Not Operate with Suspected Failures. 

If  you  suspect  there  is  damage  to  this  product,  have  it 
inspected by qualified service personnel. 
 

Do Not Operate in Wet/Damp Conditions. Do Not Operate 
in an Explosive Atmosphere. Keep Product Surfaces Clean 
and Dry 
 
 

Caution  statements  identify  conditions  or 

practices  that  could  result  in  damage  to  this  product  or 
other property.

 

 

 

Summary of Contents for AT93000

Page 1: ...USER MANUAL AT93000 System User Manual System Overview...

Page 2: ...s While using this product you may need to access other parts of the system Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system To Avoid F...

Page 3: ...ter Slave using USB Programming Mode 12 Family Board 13 Air Power and Ethernet sources 14 Site Preparation and Installation 14 Docking the TFRAME to the V93000 testhead 14 Ethernet Connections and IP...

Page 4: ...ock ordered through Advantest Part number E8028 PSD 8 Figure 9 Cassette 4 populated AT4039 plugs into Backplane 1 AT4025 into Backplane 2 9 Figure 10 SPMP Clock Connectors on ML Backplanes 1 and 2 10...

Page 5: ...op of a V93000 test head The AT93000 is compatible with CTH and STH Advantest V93000 testheads The user s DUT loadboard is hard docked on top of the TFRAME and the device handler or wafer prober is ha...

Page 6: ...ound at ATE MultiLane multilaneinc com Figure 5 shows one side of a cassette with the protective cover removed This exposed PCB is a 4 channel differential Multilane instrument The other side of the c...

Page 7: ...d Backplane Location References page 8 3 Backplane connectors Instrument PCB s inside cassettes plug into these connectors 4 Power connector 12V 6 5A each backplane for a total requirement of 13A exte...

Page 8: ...backplane 2 Instruments on the left side of cassettes are plugged into backplane 1 User documentation should be provided to explain to the cassette installer which direction to plug in the cassette T...

Page 9: ...his section If the clock is coming from the DUT or V93000 then all cassette instruments will be slaved to the external master clock In this case the external differential clock3 should be cabled to th...

Page 10: ...s can either connect from backplane 1 to backplane 2 or to the family board as shown in Figure 11 The family board connections go up through the G1A Advantest pogo block and are available to be connec...

Page 11: ...e in Figure 13 Figure 12 Backplane Reference Designators U450 is MASTER U451 is MASTER U452 is MASTER U453 is MASTER All U45x SLAVE Backplane 1 C1L C2L C3L C4L All Slave Backplane 2 C4R C3R C2R C1R Al...

Page 12: ...ep 1 Set all switches to PRG Step 2 Connect laptop to USB port shown in Figure 14 Step 3 Obtain ML AT4000 GUI Step 4 Use GUI shown in Figure 15 to set one of the instruments as the master or to set al...

Page 13: ...urrent requirements If this Family board does not suit your application and you require a different selection of V93000 tester resources a custom family board will have to be designed V93000 mapped re...

Page 14: ...paration and Installation Refer to the site preparation and installation manuals at V93000 ATE Test Solutions MultiLane multilaneinc com Docking the TFRAME to the V93000 testhead The AT93000 weighs ap...

Page 15: ...osing the appropriate ethernet connections for each instrument contact Multilane at ATE FAE multilaneinc com Software installation when controlling AT93000 via V93000 Smartest Refer to the site prepar...

Page 16: ...documentation that Multilane uses to guarantee consistent customer configurations leaving our factory Items in RED are unique for each assembly The items in RED here are an example and should be chan...

Page 17: ...ltiLane s public website o Go to ATE MultiLane multilaneinc com o Scroll down MultiLane Instruments for V93000 Click on any instrument eg AT4039E o You will find the instrument GUI here Connect the po...

Page 18: ...to control MASTER SLAVE clock selection Figure 17 AT4000 REV B Backplane Figure 18 AT4000 REV B cable connection options between backplanes To set MASTER SLAVE refer to the following table U450 is MA...

Page 19: ...cassette s Jan 14 2021 0 9 2 Changed U13 to 0 for ALL SLAVE configuration March 2 2021 0 9 3 Appendix 4 Added Appendix showing system block diagram Oct 26 2021 0 9 4 All Updated all sections to reflec...