Event Descriptions
42
Event Descriptions
Event
Fault LED
Fault Relay
Default
Contact ID
Reporting
Fault relay &
Contact ID delay
AC
Instant
Relay 1
Enabled
15 minutes
Tamper
Instant
Relay 1
Enabled
Instant
Zone 1
Instant
Relay 1
Enabled
Zone 2
Instant
Relay 1
Enabled
Zone Lockout
NA
Not Mapped
Enabled
Ethernet
Instant (Disabled by Default)
Relay 2
Disabled
Multicom Power
&\FOH1RWLÀFDWLRQ
NA
RF Transmitter
Enabled
10 minutes
Poll Fail
NA
Relay 2
Disabled
90 seconds
Fault Outputs
There are four mapping options for the 2 on board
relays:
1� Not Mapped
- The relays are able to be
remotely controlled via the Activations
Centre
2� Communications
- Communications has not
worked for the programmed period of time
Event Descriptions
Event Default Table
3� External Zone / Tamper
- The output will
trigger while the Tamper is open, or, any of
the on board zones are not sealed with the
appropriate EOLR.
4� Power Fault
- The output will trigger after the
programmed power fault time.
Note: See Option 38 for Relay Mapping.