38
39
Programming Options
Programming Options
Test report time
/ Default: 24
*
3
1
2
4
#
The time between test reports for the Multicom (in
hours), default 24 hours.
Ethernet Fault Timer
/ Default: 240
*
3
5
2
4
0
#
This controls the time interval for either Contact
ID reporting or relay events. This setting is
DXWRPDWLFDOO\FRQÀJXUHGEDVHGRQ(WKHUQHW
polling rate. See options 39 for enabling CID
QRWLÀFDWLRQ
Relay mapping
/ Default: 122
SMS
3 8
A B C
DTMF
* 3 8
A B
C
#
ABC, where
A
= COMM’s fail event,
B
= Aux alarm
event (Batt + AC),
C
= External alarm (Zone1-2 and
tamper). Each event can be mapped to:
0
= Not Mapped,
1
= Relay 1,
2
= Relay 2.
Contact ID Event enable/disable
/ Default:1011
*
3
9
A
B
C
D
#
To disable Event set to 0, to enable set to 1. Default
is all zones enabled. Zones are all 24 hour zones.
Where:
A
0XOWLFRP3RZHU3RLQW3RZHU&\FOH1RWLÀFDWLRQ
B
= Poll Fail
C
= Power Fault
D
= Ethernet fault
Go to Program Code
/ Default: 1345
*
4
0
1
3
4
5
#
Installer Program code used by NTD
Ethernet DHCP Enable / Disable
/ Default: 1
*
5
6
1
#
$OORZV\RXWRFRQÀJXUHWKH(WKHUQHWDVHLWKHU
Static or DHCP. When DHCP is disabled, you must
FRQÀJXUHDVWDWLF,3(QWHUWRHQDEOH'+&3RU
to disable.