MULTICOM 5 PLUS INSTALLER MANUAL
9
Hardware Descriptions
1)
MODE3 LOOPED
When this LED is active,
the PSTN connects the Mode 3
connections.
When this LED is inactive, the
Mode 3 connections are passed from PSTN
to PANEL.
2)
PSTN
Connects to standard PSTN.
3)
ISOLATE
When this LED is active, the
Alarm Panel is not connected to PSTN, it is
connected to the Multicom only.
When this LED is inactive, the Alarm Panel
is connected to PSTN.
4)
PANEL
Connects to the Alarm Panel or
other communications device.
5)
AC1 and AC2
The Multicom is powered
by 16Vac 1 Amp power supply.
6)
+BATT and –BATT
Connect a standard
12V Sealed Lead Acid type battery. The
Multicom has a tri-state charger designed
to help optimize battery life and
performance.
7)
PROG1 & PROG2
Custom interfaces may
be incorporated to the Multicom using
these pins. Please contact your supplier
for specialist interface requirements. There
are several thermal sensors, data
interfaces which can be interfaced with
for local / remote monitoring.
8)
12V & GND
Auxiliary 12V power can be
taken from these pins. The load must not
exceed 200mA. This output has a
resettable fuse, which will automatically
reset once any overload condition is
removed.
9)
ZONE1, ZONE2, ZONE3 & ZONE4
Each
zone requires a 3K3 End Of Line resistor to
be 'sealed'. All zones operate as 24hour
alarm inputs & are not enabled by default.
10)
R1COM, R1 NC, R1 NO
Relay 1 is
programmed as a communications fault
relay. If there is no communication path
available for longer than the pre
programmed time this will active until
communications are restored.
11)
R2COM, R2 NC, R2 NO
Relay 2 is
programmed as an alarm output. This will
activate when an alarm condition is
active on the MC5P (Zone, AC Fail, Batt
Fail, Tamper active)
Note: Either relay can be programmed to
be remotely activated for remote
arm/disarm or other access control
functions. Each relay can also have
specific events trigger the relay
12)
TAMPER
Connect to the case tamper,
this circuit requires a normally closed
tamper (no EOLR required)
13)
SERIAL
Allows for configuration and
analysis of the Multicom. This requires a
MPC-cable and the PC Multicom Analysis
Tool Software.
14)
ETHERNET
Connect the Multicom's
Ethernet socket to any spare Ethernet port
on the site's network, which will allow
access to the Internet. Some networks
(firewalls/gateways) may require port 5000
to 5010 (TCP & UDP) be opened on the
internet gateway device. By default, you
will require DHCP to be enabled on the
network, contact the sites IT support staff
for configuration requirements.
15)
BLUETOOTH
Allows for wireless
configuration and analysis of the
Multicom. The Bluetooth interface can be
used with the Multicom Analysis Tool
software on a PC with an inbuilt or USB
dongle Bluetooth device.
16)
SIM CARD
A Surepoll enabled sim card
must be installed for GPRS/GSM operation.
17)
GSM/GPRS
The GSM / GPRS Antenna
must be installed. For reliable operation
there must be at least 2 bars of signal at
the time of commissioning. The system
may work on one bar however this is not
an acceptable level.