Nine: Checking Out and Verifying the System
73
Providing a brighter solution.™
What to do
If it doesn’t work
Reference/Procedure
Verify that the PE953
Hand-Held Controller will
communicate with the PE653
Device from everywhere on
your property.
Review the Section
covering
“Testing Z-Wave
Reception”
starting on
page 50.
Carry the PE953 Hand-Held Controller to several parts
1.
of the area from which commands might be sent to the
PE653 Device.
Test the reception by turning connected equipment ON
2.
and OFF.
Note if the PE653 Device fails to respond immediately
3.
to any of the commands sent.
If commands are missed, follow the instructions for
4.
“Moving the Antenna to a Better Location’
starting on
page 50.
What to do
If it doesn’t work
Reference/Procedure
Verify that the (POOL/SPA
switch on the PE953 Hand-
Held Controller activates
the Motorized Valve
Actuators (if installed)
Verify that the PE953
Hand-Held Controller is
configured for BOTH (Pool
and Spa)
If necessary, press and release any button on the Hand-
1.
Held controller to wake it from sleep.
Look for the word POOL at the lower right part of the
2.
PE953 screen (refer to illustration on page 4).
If either POOL or SPA is observed, press and release
3.
the
P/S
button on the PE953.
Verify that the word POOL switches to SPA and back to
4.
POOL each time that the
P/S
button is pressed.
Verify that the water flows to the Pool when POOL is
5.
shown in the screen.
Verify that the water flows to the SPA when SPA is
6.
shown in the screen.
Correct the Motorized Valve
Actuator Synchronization if
the water flow is incorrect.
Refer to Section 3:
Motorized Valve Actuator Connection
and Synchronization
starting on page 36.