Configuring the job computer
Configuring the nozzles - for sprayers with pressure calculation
52
V1.20190404
3030383000-02-EN
4.
In the “Results” area, you can see the speed at which the application rate can be achieved.
Calibrate the nozzles
“Calibration” screen
Selected nozzle
Nozzle output at 3 bar - Result of the
calibration
Current nozzle output. When you change the
pressure, the newly calculated nozzle output
appears.
For non-standard nozzles, the calibration must
be repeated at a different pressure. This
pressure should be about as high as the
intended working pressure.
WARNING
Spray liquid or spray liquid residues
Danger of poisoning or chemical burning
◦
Clean the spray liquid tank thoroughly prior to calibration. The sprayer must be free of spray
liquids or spray liquid residues.
◦
Use only clear water during calibration.
◦
Wear required protective equipment.
Calibrate a standard nozzle as follows:
The tank is filled with clear water.
There are no spray liquid residues in the tank or the pipelines.
1.
- On the work screen, switch the application mode to manual.
2.
- Start application
3.
and
- Set the spray pressure to 3 bar.
4.
Using a measuring cup, collect the water from several nozzles for one minute each.