6
Operating job computer on the field
Switching the fans on and off
36
V1.20190404
3030383000-02-EN
Function icon
Function
Resets the “Distance” counter.
Resets the “Work time” counter.
Pressed briefly: Continue to the total counters
Pressed long: Back to the work screen
Clears the contents of the displayed trip counter.
Stops the trip counter.
- The documentation of the work will be stopped until the terminal is
restarted or the function button is pressed again.
- The icon is flashing on the work screen:
Next trip counter. (Optional function)
Activates the trip counter. (Optional function)
Previous trip counter. (Optional function)
Switching the fans on and off
You can switch the fan on and off during operation.
This is how you reach the screen with this function:
To switch the fan on and off:
1.
/
/
- Press the function key for the left, centre or right fan.
⇨
The work screen displays the respective icon:
/
/
⇨
The respective fan will be switched on.
2.
/
/
- Press the function key again to switch the corresponding fan off
again.
If the implement is equipped with an automatic fan system, it can be configured so that the respective
fan is automatically switched on or off for specific section combinations.
Switching the air compressor on and off
The system works with two types of compressors:
6.9
Path
Procedure
6.10