6
Operating job computer on the field
Regulating the application rate
32
V1.20190404
3030383000-02-EN
Function icon
Function
Increases the target rate by 10%.
Reduces the target rate by 10%.
Restores the target rate back to 100%.
To change the target rate during work:
1.
- Activate automatic steering.
2.
- Open main valve.
⇨
Spray cones appear under the boom icon on the work screen. Still, the sprayer is not
spraying.
⇨
As long as you are at a standstill, the sprayer cannot start spraying. See icons:
and
3.
Exceed the speed defined in the “Regulation off below” parameter.
⇨
The sprayer begins adjusting the application rate to the defined target rate.
4.
or
- Press to change the target rate.
⇨
The degree of change appears on the work screen.
5.
- Restores the original target rate.
Setting target rate
The target rate is the quantity of spray liquid you want to apply per hectare.
The job computer will attempt to maintain this rate during the work.
There are several ways to specify the rate:
▪
Enter rate on the “Parameters” screen. [
▪
The target rate can be adopted from external sources using the “ISOBUS-TC” app:
– from tasks,
– from prescription maps,
– from external sensors.
Target rate from parameters
Target rate from an external source
Procedure
6.4.3
Methods
Illustration