12 | 16
M0404.docx | Rev 1.8 | Modified on 26/09/2018 | © Remote Control Technologies Pty Ltd
Service Information
Service Schedule
The manufacturer recommends
that the following service procedure should be performed at each machine’s
scheduled service interval.
Service Procedure
1.
Perform a visual inspection; include the following:
a) Control unit.
b) Wiring connections and looms.
c) Check that the speed sensor is in good working condition.
2.
Perform a system test. (Refer to the
Operation and Use
section in this manual for information on how the
controller operates.)
a) For any problems found when testing the controller, refer to the
Troubleshooting
section further in this
manual.
Parts List
Parts Included with the 3515 Speed Alert Controller
Part No. Description
Qty
3515
Speed Alert Control Unit
1
Parts Included with the 3508 Industrial Speed Alert Kit
Part No. Description
Qty
3510
Loom to suit Industrial Speed Alert Kit
1
11109
LED 6-32 Volt Red 2T
1
4040
Strobe Light Blue 4” 12–48 V
1
3515
Speed Alert Control Unit
1
4804
Signal Amplifier (not supplied with the kit, order if necessary for
installation
of the 3515
control unit)
0
Compliance and Standards
RCT has an obligation as a manufacturer to comply with the regulations as required by the relevant regulatory
bodies, depending on the market and location.
This product currently complies with the following:
ACMA
CISPR 22:2006 Class A procedures
– Information technology equipment – Radio disturbance
characteristics
– Limits and methods of measurement
EU
EMC Directive 2004/104/EC
RoHS Directive 2011/65/EU
FCC
This device is exempt from FCC regulations under 47 CFR 15.103 Exempted devices
IC
This device is exempt from IC regulations under ICES-003
— Information Technology
Equipment (ITE)
— Limits and Methods of Measurement