M0404.docx | Rev 1.8 | Modified on 26/09/2018 | © Remote Control Technologies Pty Ltd
13 | 16
Troubleshooting
Technical Specifications
Dimensions, control unit only:
Length: 65 mm | Width: 37 mm | Height/Depth: 23 mm
Dimensions, boxed for freight:
Length: 300 mm | Width: 200 mm | Height/Depth: 100 mm
Weight, control unit only:
0.19 kg
Weight, including loom and
packaging for freight:
0.20 kg
Input voltage:
12 to 24 Vdc
Operating temperature range:
0 to 70 °C
Connection types:
8-pin Deutsch receptacle
Inputs:
Ignition, earth, speed signal input
Min & max input voltage:
8 to 35 Vdc
Circuit protection:
Reverse polarity protection
Enclosure type:
LCM
Environmental protection IP rating:
IP67
Programming/adjustment:
YES (through the use of the onboard HEX switch)
Frequency input voltage hysteresis:
4 V high, 2 V low
Continuous carrying current:
10 A
Input filter:
Single pole at 100 kHz
Response time (freq > 15 Hz):
Better than 120 ms
Response time (freq < 15 Hz):
Better than 2 cycles
Frequency tolerance (0
–50 °C):
± 0.5%
Detect jitter:
Less than 0.25%
Adjustable trip frequency:
Yes (0.01 Hz to 25 kHz)
Adjustable release frequency:
Yes (0.01 Hz to 25 kHz)
– will force 1% lower than trip frequency
Fault
Remedy
Relay outputs do not activate at desired
speed.
Perform a factory restore 06c8 and reprogram the relay trip
frequencies
Note
: Relay trip frequencies in programming mode are half the
desired trip frequency.
The unit will not program or program
instructions do not yield the desired
outcome.
Perform a factory restore 06c8 and reprogram desired
parameters.