5. DIRECT VENTING WITH FACTORY BUILT CHIMNEY
5.1 DIRECT VENT REQUIREMENTS USING FACTORY BUILT CHIMNEYS
•
Oven installations utilizing direct vent insulated chimneys must comply with UL 737 and NFPA 96
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
•
Factory built insulated chimneys must be listed to UL 103 HT or ULC S627.
•
Example chimney pipe: Simpson DuraTech www.duravent.com
•
Applicable for building with chimneys 3 stories or less
•
2 sets of offsets (elbows) allowed (15 or 30 degree angles only)
•
Attach chimney anchor plate to oven using
Direct Vent Flue Adaptor - part# DVA
•
Chimney must be installed per chimney manufacturer’s installation instructions
•
Chimney must terminate to an approved chimney cap with spark arrestor (screen mesh)
•
Chimney lengths 25 feet or longer may require an exhaust fan. The Enervex GSV series fan is listed
for use with a wood burning pizza oven see: http://www.greasefans.com
•
Applicable for pizza and bread products only
5.2 ADDITIONAL REQUIREMENTS FOR CANADA
•
The use of smoke detectors is highly recommended
•
The chimney connector shall not pass through an attic, roof space, closet floor, ceiling, or similar
concealed space. Where passage through a wall or partition of combustible construction is desired,
the installation shall conform with CAN/CSA-B365
5.3 OVEN FLUE OUTLET
•
Flue size: 8” round (internal diameter)
•
Flue location: on top of oven centered above arch, 7 3/8”
(+/- 1”) behind the front panel
5.4 CONNECTING FACTORY
BUILT CHIMNEY TO OVEN
Mugnaini offers an optional Direct Vent Flue Adaptor for
installation in the factory. Part# DVA is a flush mount adaptor
designed to accept a standard Anchor Plate used with UL 103
double wall insulated chimney.
Part# DVA
with anchor plate adaptor