Service and Automation Module SAM
1 Module cassette, slots for
additional I/O PIM cards
2 Compact Flash memory
card
3 Display for fault code and
Mini Dialog
4 Control keys for Mini Dialog
5 Diagnostic lamp
6 Interface for dialog unit
7 Connector with spring-cage
terminal connections
SAM functions
• Display of fault codes from engine governor and SAM (3).
• Backup function, engine life data are stored
– every hour,
– after every engine stop,
– after every emergency engine stop.
• Interface for dialog unit.
Diagnosis
• Straightforward diagnosis by fault code display.
• Self-diagnosis by diagnostic lamp (5).
– Steady = SAM is OK.
– Flashing = SAM is faulty, contact Service.
– Dark = No power supply.