153246 – HIHI Knock Integrator A6
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
153247 – HIHI Knock Integrator A7
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
153248 – HIHI Knock Integrator A8
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
153249 – HIHI Knock Integrator A9
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
153250 – HIHI Knock Integrator A10
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
MS150034/04E 2016-11
| Troubleshooting | 101
TIM-ID: 0000017543 - 001