202 – SD T-Fuel
Red alarm; power reduction ≥ 20%
Cause
Corrective action
Fuel temperature sensor faulty;
short circuit or wire break.
u
Check sensor B33 and wiring, replace as necessary
(→ Page 149).
203 – SD T-Charge Air
Yellow alarm; power limitation < 20%;
Cause
Corrective action
Charge-air temperature sensor
faulty; short circuit or wire
break.
u
Check sensor B9 and wiring, replace as necessary
(→ Page 149).
204 – SD Lube Oil Level (Option)
Optional yellow alarm; warning
Cause
Corrective action
Lube oil level sensor faulty;
short circuit or wire break.
u
Check sensor B24 and wiring, replace as necessary
(→ Page 149).
205 – SD T-Coolant Intercooler
Yellow alarm; warning
Cause
Corrective action
Intercooler coolant temperature
sensor faulty; short circuit or
wire break.
u
Check sensor B26 and wiring, replace as necessary
(→ Page 149).
206 – SD T-Exhaust A
Yellow alarm; warning
Cause
Corrective action
Exhaust temperature sensor on
A-side faulty; short circuit or
wire break.
u
Check sensor B4.21 and wiring, replace as necessary
(→ Page 149).
207 – SD T-Exhaust B
Yellow alarm; warning
Cause
Corrective action
Exhaust temperature sensor on
B-side faulty; short circuit or
wire break.
u
Check sensor B4.22 and wiring, replace as necessary
(→ Page 149).
58 | Troubleshooting | MS15042/00E 2014-10
TIM-ID: 0000016866 - 006