91 – SS No Runup Speed
Yellow alarm; warning
Cause
Corrective action
Runup speed not reached.
1. Check battery.
2. Check starter.
3. Initiate new starting attempt.
4. Request towing locomotive if required.
92 – SS No Starter Speed
Yellow alarm; warning
Cause
Corrective action
Starter speed not reached;
termination of starting
sequence; starter does not turn
or turns slowly.
1. Initiate new starting attempt.
2. Check voltage at starter power supply.
3. Request towing locomotive if required.
93 – SS T-Preheat
No alarm, fault is registered.
Cause
Corrective action
Preheating temperature too low;
coolant temperature too low for
engine start. Significantly
increased engine wear. Engine
start might be inhibited by the
locomotive control system.
Engine may be started in
emergency situations only.
1. Extend preheating period.
2. Check preheating unit.
94 – LO T-Preheat
Yellow alarm; warning
Cause
Corrective action
Preheating temperature too low;
coolant temperature too low for
engine start. Excessive engine
wear. Engine start might be
inhibited by the locomotive
control system. Engine may be
started in emergency situations
only.
1. Extend preheating period.
2. Check preheating unit.
102 – AL Consumption Meter Faulty
Yellow alarm; warning
Cause
Corrective action
Consumption meter faulty.
u
Contact Service.
54 | Troubleshooting | MS15042/00E 2014-10
TIM-ID: 0000016866 - 006