1.4520.614 – MIC5 ISE Secondary Open Cylinder 5
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 5 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.615 – MIC5 ISE Secondary Open Cylinder 6
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 6 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.616 – MIC5 ISE Secondary Open Cylinder 7
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 7 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.617 – MIC5 ISE Secondary Open Cylinder 8
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 8 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.618 – MIC5 ISE Secondary Open Cylinder 9
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 9 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.619 – MIC5 ISE Secondary Open Cylinder 10
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 10 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.620 – MIC5 ISE Secondary Open Cylinder 11
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit of
cylinder 11 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
MS150104/02E 2016-11
| Troubleshooting | 99
TIM-ID: 0000038611 - 003