1.4520.593 – MIC5 IPE Prim Short Circuit Cyl 4
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 4 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.594 – MIC5 IPE Prim Short Circuit Cyl 5
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 5 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.595 – MIC5 IPE Prim Short Circuit Cyl 6
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 6 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.596 – MIC5 IPE Prim Short Circuit Cyl 7
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 7 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.597 – MIC5 IPE Prim Short Circuit Cyl 8
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 8 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.598 – MIC5 IPE Prim Short Circuit Cyl 9
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 9 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.599 – MIC5 IPE Prim Short Circuit Cyl 10
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 10 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
96 | Troubleshooting | MS150104/02E 2016-11