1.4520.586 – MIC5 IPE Primary Open Cylinder 17
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 17 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.587 – MIC5 IPE Primary Open Cylinder 18
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 18 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.588 – MIC5 IPE Primary Open Cylinder 19
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 19 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.589 – MIC5 IPE Primary Open Cylinder 20
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 20 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.590 – MIC5 IPE Prim Short Circuit Cyl 1
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 1 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.591 – MIC5 IPE Prim Short Circuit Cyl 2
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 2 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
1.4520.592 – MIC5 IPE Prim Short Circuit Cyl 3
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 3 in ignition sequence.
1. Check cabling to ignition coil (→ Page 201).
2. Check ignition coil.
MS150104/02E 2016-11
| Troubleshooting | 95
TIM-ID: 0000038611 - 003