1.4520.635 – MIC5 ISE Secon Short Circuit Cyl 6
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 6 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.636 – MIC5 ISE Secon Short Circuit Cyl 7
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 7 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.637 – MIC5 ISE Secon Short Circuit Cyl 8
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 8 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.638 – MIC5 ISE Secon Short Circuit Cyl 9
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 9 in ignition sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.639 – MIC5 ISE Secon Short Circuit Cyl 10
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 10 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.640 – MIC5 ISE Secon Short Circuit Cyl 11
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 11 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
102 | Troubleshooting | MS150104/02E 2016-11
TIM-ID: 0000038611 - 003