215 – SD P-HD
ZKP-Number: 1.8004.567
Signal error, rail pressure sensor
Yellow alarm; high-pressure regulator emergency operation
Cause
Corrective action
Rail pressure sensor faulty. ==>
high-pressure regulator
emergency operation.
Short circuit or wire break.
1. Check sensor and wiring (B48), replace as necessary
(→ Page 248).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
216 – SD T-Lube Oil
ZKP-Number: 1.8004.575
Signal error, lube oil temperature sensor
Yellow alarm; warning
Cause
Corrective action
Lube oil temperature sensor
faulty.
Short circuit or wire break.
1. Check sensor and wiring (B7), replace as necessary
(→ Page 248).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
219 – SD T-Intake Air
ZKP-Number: 1.8004.573
Signal error, intake air temperature sensor
Yellow alarm; warning
Cause
Corrective action
Intake air temperature sensor
faulty.
Short circuit or wire break.
1. Check sensor and cabling (B3), replace as necessary
(→ Page 248).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
220 – SD Level Coolant Water
ZKP-Number: 1.8004.584
Signal error, coolant level sensor
Yellow alarm; warning
Cause
Corrective action
Coolant level sensor faulty.
Short circuit or wire break.
1. Check sensor and cabling (F33), replace as necessary
(→ Page 248).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
122 | Troubleshooting | MS150110/00E 2013-10
TIM-ID: 0000045495 - 001