337 – AL Wiring Cylinder B7
ZKP-Number: 1.8004.536
Wiring fault cylinder B7
Yellow alarm; misfire
Cause
Corrective action
Short circuit fault in injector
wiring cylinder B7.
1. Check injector solenoid, replace injector if necessary
(→ Page 182).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
338 – AL Wiring Cylinder B8
ZKP-Number: 1.8004.537
Wiring fault cylinder B8
Yellow alarm; misfire
Cause
Corrective action
Short circuit fault in injector
wiring cylinder B8.
1. Check injector solenoid, replace injector if necessary
(→ Page 182).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
339 – AL Wiring Cylinder B9
ZKP-Number: 1.8004.538
Wiring fault cylinder B9
Yellow alarm; misfire
Cause
Corrective action
Short circuit fault in injector
wiring cylinder B9.
1. Check injector solenoid, replace injector if necessary
(→ Page 182).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.
340 – AL Wiring Cylinder B10
ZKP-Number: 1.8004.539
Wiring fault cylinder B10
Yellow alarm; misfire
Cause
Corrective action
Short circuit fault in injector
wiring cylinder B10.
1. Check injector solenoid, replace injector if necessary
(→ Page 182).
2. Fault is rectified when engine is restarted (→ Page 80).
3. Contact Service.