RAW WATER CIRCUIT (open circuit)
Number of cylinders
12
Raw water pump: inlet pressure, min.
L
bar
-0.2
Raw water pump: inlet pressure, max.
L
bar
0.5
Pressure loss in off-engine raw water system, max.
L
bar
0.7
LUBE-OIL SYSTEM
Number of cylinders
12
Lube oil operating temperature before engine, from
R °C
72
Lube oil operating temperature before engine, to
R °C
83
Lube oil operating pressure before engine, from
R bar
6
Lube oil operating pressure before engine, to
R bar
8
Lube oil operating pressure (low idle) (meas. point: before engine)
R bar
2.0
FUEL SYSTEM
Number of cylinders
12
Fuel pressure at engine inlet connection, min. (when engine is starting)
L
bar
-0.1
Fuel pressure at engine inlet connection, min. (when engine is running)
L
bar
-0.3
Fuel pressure at engine inlet connection, max. (when engine is starting)
L
bar
1.5
Fuel supply flow, max.
R Liters/
min
29
GENERAL OPERATING DATA
Number of cylinders
12
Firing speed, from
R rpm
80
Firing speed, to
R rpm
120
STARTING (electric)
Number of cylinders
12
Rated starter voltage (standard design)
R V=
24
STARTING (with compressed air/hydraulic starter)
Number of cylinders
12
Starting-air pressure before starter, min.
R bar
8
Starting-air pressure before starter, max.
R bar
9
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders
12
Longitudinal inclination, continuous max. driving end down (Option: max. oper-
ating inclinations)
L
Degrees
15
Longitudinal inclination, temporary max. driving end down (Option: max. oper-
ating inclinations)
L
Degrees
22.5
MS150045/02E 2013-07 | Technical Data | 57
TIM-ID: 0000010953 - 002