596 – AL Develop PR Set
ZKP-Number: 18.004.645
Cause
Corrective action
The parameter set used is a test
parameter set.
u
The alarm remains active until a series-production parameter
set was installed.
600 – SD T-Exhaust A+B
ZKP-Number: 18.004.646
Cause
Corrective action
SD T-Exhaust A and T-Exhaust B
u
Check sensor and cabling, replace as necessary.
601 – SD ETC1+ETC2
ZKP-Number: 13.011.227
Cause
Corrective action
SD ETC1 and ETC2
u
Check sensor and cabling, replace as necessary.
625 – SD P-Fuel before Prefilter
ZKP-Number: 18.004.600
Cause
Corrective action
Analog input signal for pressure
before prefilter faulty; Short
circuit or wire break
1. Check pressure sensor and cabling, replace as necessary.
2. Error cleared after restarting the engine.
138 | Troubleshooting | MS150045/02E 2013-07
TIM-ID: 0000018389 - 003