2.5.5 16V 4000 M23S engine data, RheinSchUO, stage II, IMO Tier II
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N Not yet defined value
- Not applicable
X Applicable
Heat exchanger
mounted
Heat exchanger
separate
Application group
3A
3A
3A
3A
Intake-air temperature
°C
25
45
25
45
Charge-air coolant temperature
°C
--
--
--
--
Raw-water inlet temperature
°C
25
32
25
32
Barometric pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
POWER DATA (power ratings are net brake power as per ISO 3046)
Heat exchanger
mounted
Heat exchanger
separate
Rated engine speed
A
rpm
1800
1800
1800
1800
Continuous power ISO 3046 (10% over-
load capability, design power DIN 6280,
ISO 8528)
A
kW
1840
1840
1840
1840
GENERAL CONDITIONS (for maximum power)
Heat exchanger
mounted
Heat exchanger
separate
Intake depression (new filter)
A
mbar
15
15
15
15
Intake depression, max.
L
mbar
30
30
30
30
MODEL-RELATED DATA (basic design)
Heat exchanger
mounted
Heat exchanger
separate
Cylinder arrangement: V-angle
Degrees
(°)
90
90
90
90
Bore
mm
170
170
170
170
Stroke
mm
210
210
210
210
Cylinder displacement
Liters
4.77
4.77
4.77
4.77
Total displacement
Liters
76.3
76.3
76.3
76.3
Number of inlet valves per cylinder
2
2
2
2
Number of exhaust valves per cylinder
2
2
2
2