RAW-WATER CIRCUIT (open circuit)
Heat exchanger
mounted
Heat exchanger
separate
Raw-water pump: Inlet pressure, min.
L
bar
-0.4
-0.4
--
--
Raw-water pump: Inlet pressure, max.
L
bar
1.0
1.0
--
--
Pressure loss in engine-external raw-water
system, max.
L
bar
N
N
--
--
LUBE-OIL SYSTEM
Heat exchanger
mounted
Heat exchanger
separate
Lube-oil operating temperature before en-
gine, from
R
°C
84
85
84
85
Lube-oil operating temperature before en-
gine, to
R
°C
92
93
92
93
Lube-oil operating pressure before engine,
from
R
bar
5.5
5.5
5.5
5.5
Lube-oil operating pressure before engine,
to
R
bar
6.5
6.5
6.5
6.5
Lube-oil operating pressure (low idle)
(meas. point: before engine)
R
bar
FUEL SYSTEM
Heat exchanger
mounted
Heat exchanger
separate
Fuel pressure at supply connection to en-
gine, min. (when engine is starting)
L
bar
-0.1
-0.1
-0.1
-0.1
Fuel pressure at supply connection to en-
gine, min. (when engine is running)
L
bar
-0.3
-0.3
-0.3
-0.3
Fuel pressure at supply connection to en-
gine, max. (when engine is starting)
L
bar
1.5
1.5
1.5
1.5
Fuel supply flow, max.
A
Liters/
min
GENERAL OPERATING DATA
Heat exchanger
mounted
Heat exchanger
separate
Firing speed, from
R
rpm
80
80
80
80
Firing speed, to
R
rpm
120
120
120
120
STARTING SYSTEM (electric)
Heat exchanger
mounted
Heat exchanger
separate
Rated starter voltage (standard design)
R
V=
24
24
24
24
60 | Product Summary | MS150068/01E 2014-01