6.18 Battery-Charging Generator
6.18.1 Battery-charging generator drive – Coupling condition check
Preconditions
☑
Engine is stopped and starting disabled.
Battery-charging generator drive
– Coupling condition check
1.
Remove screws (1).
2.
Remove protective cover (2).
3.
Check resilient coupling (3) for cracks and
plastic deformation.
4.
If there is serious deformation or crack for-
mation, contact Service.
5.
Install protective cover (2) with screws (1).