181 – AL CAN2 Node Lost
Yellow alarm.
Associated parameter 2.0500.681
Cause
Corrective action
Bus node (SAM or EMU) lost on
CAN bus 2.
u
Check operation of bus nodes and cabling. Buses (CAN bus 1
and CAN bus 2) are redundant.
182 – AL CAN Wrong Parameters
Red alarm.
Associated parameter 2.0500.682
Cause
Corrective action
Incorrect parameter values
entered in data record.
u
Contact Service (configuration fault).
183 – AL CAN No PU-Data
Red alarm.
Associated parameter 2.0500.683
Cause
Corrective action
The selected CAN mode
initializes communication by
means of the PU data module.
However, the necessary PU data
module is not present or is
invalid.
u
Contact Service (configuration fault).
184 – AL CAN PU-Data Flash Error
Red alarm.
Associated parameter 2.0500.684
Cause
Corrective action
A programming error occurred
when attempting to copy a
received PU data module into
the Flash module.
u
Contact Service (configuration fault).
186 – AL CAN1 Bus Off
Yellow alarm.
Associated parameter 2.0500.686
Cause
Corrective action
CAN controller 1 is in “Bus Off”
status. Automatic switching to
CAN bus 2. Bus users (ECU,
SAM or EMU) faulty.
u
Check operation of bus nodes and cabling.
MS150114/01E 2015-03
| Troubleshooting | 103
TIM-ID: 0000044738 - 001