![MTU 12 V 2000 S96 Operating Instructions Manual Download Page 32](http://html1.mh-extra.com/html/mtu/12-v-2000-s96/12-v-2000-s96_operating-instructions-manual_1852634032.webp)
3.10 Emergency stop
CAUTION
An emergency stop causes extreme stress to the engine.
Risk of overheating, damage to components!
• Initiate emergency stop only in emergency situations.
Emergency stop
Item
Action
Emergency stop pushbut‐
ton
Press EMERGENCY STOP button.
• Engine is stopped by disconnecting the power supply to the ECU;
• Emergency air shutoff flaps close (if provided);
• signalization (e.g. by horn, beacon) is activated.
After emergency stop
Item
Action
Switchgear cabinet, control
panel etc. (depending on
manufacturer)
Press pushbutton for alarm acknowledgment.
• Audible and visual signalization stops.
Engine
Manually open emergency air shutoff flaps (if provided).
• Engine is ready for starting.
32 | Operation | MS150095/01E 2012-08
TIM-ID: 0000002307 - 002