![MTU 12 V 2000 S96 Operating Instructions Manual Download Page 112](http://html1.mh-extra.com/html/mtu/12-v-2000-s96/12-v-2000-s96_operating-instructions-manual_1852634112.webp)
6.18.5 Humidity sensor – Replacement
Preconditions
☑ Engine is stopped and starting disabled.
☑ Preliminary steps are completed.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Torque wrench, 10-60 Nm
F30510423
1
Ratchet adapter ½"
F30027340
1
Engine
1
NOx sensor
1
CAUTION
Contamination of components.
Damage to component!
• Observe manufacturer's instructions.
• Check components for special cleanness.
NOx sensor – Removal
1.
Observe the following general information:
• Layout and position of sensor
(→ Page 107).
2.
Unplug and remove male connector.
3.
Remove screws (1).
4.
Remove sensor (2).
112 | Task Description | MS150095/01E 2012-08
TIM-ID: 0000025206 - 001