4 Operation
4.1 Putting the engine into operation after extended out-of-service
periods (>3 months)
Preconditions
☑
Engine is stopped and starting disabled.
☑
MTU Fluids and Lubricants Specifications (A001061/..) are available.
Putting into operation after long out-of-service periods (>3 months)
Item
Action
Engine
Depreserve (→ Preservation and Represervation Specifications (A001070/
…)).
Lube oil system
Check engine oil level (→ Page 71).
Fuel system
Connect appropriate equipment to fuel supply line to fill the system.
Fuel system
Vent (→ Page 58).
Coolant circuit
If engine is out of service for more than one year, change engine coolant
(→ Page 82). Change charge-air coolant (→ Page 90).
Coolant circuit
Check engine coolant level (→ Page 81); Check charge-air coolant level
(→ Page 89).
Coolant circuit
Preheat engine coolant with coolant preheating unit (if fitted).
Engine governor
Check plug-in connections (→ Page 108).
Engine control system
Switch on.
MS150111/01E 2014-05
| Operation | 21
TIM-ID: 0000010073 - 003