background image

12.  Environment 
 

 

Do not dispose electrical appliances as unsorted municipal waste, use separate 
collection facilities. 

 

Contact your local government for information regarding the collection systems 
available. 

 

If electrical appliances are disposed of in landfills or dumps, hazardous substances 
can leak into the ground water and get into the food chain, damaging your health 
and well-being. 

 

When replacing old appliances with new ones, the retailer is legally obligated to 
take back your old appliance for disposal at least for free of charge. 

 

13.  Ingress protection (IP) ratings 

 

 

Ingress protection numbers are used to specify the environmental protection – 
electrical enclosure – of electrical equipment. 

 

The IP rating normally has two numbers: 

1.

 

The first number – protection against solid objects. 

2.

 

The second number – protection against liquids. 

 

IP64: 

The instrument is totally protected against dust and against water sprayed from all  
directions. 

 

Warranty Clause 

MTP  Instruments

  warrants  this  instrument  to  be  free  of  defects  in  parts  and 

workmanship for one (1) year from date of shipment.  This warranty does not apply to 
defects  resulting  from  action  of  the  user  such  as  misuse,  improper  wiring,  operation 
outside of specification, improper maintenance or repair, or unauthorized modification.  

MTP  Instruments

 specifically disclaims any implied warranties or merchantability or 

fitness  for  a  specific  purpose  and  will  not  be  held  liable  for  any  direct,  indirect, 
incidental  or  consequential  damages.   

MTP  Instruments

  total  liability  is  limited  to 

repair or replacement of the product. 
 
 
 
 
 
 
 
 
 
 
 

11 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for MTP-1032

Page 1: ...MTP Instruction Manual Voltage Tester Model MTP 1032 MTP Instruments www com information itm com 1 800 561 8187...

Page 2: ...Page 4 6 Measurement Page 5 6 1 Voltage test double pole test Page 5 6 2 Phase rotation test Page 6 6 3 Continuity test Page 7 6 4 Pen light function Page 7 7 Battery replacement Page 8 8 Specificatio...

Page 3: ...Safety Warnings This instruction manual contains warnings and safety rules which have to be noticed by the user to ensure safe operation of the instrument and to maintain it in safe condition Therefo...

Page 4: ...nts Verify proper operation on a known source before taking action as a result of the indication Never attempt to make any measurement in any abnormal conditions such as a broken case or exposed metal...

Page 5: ...tection cover 4 Preparation for Measurement 4 1 Auto Power on Self Diagnostic Test Auto Power on Short circuiting the probes as follows powers on the instrument automatically and goes into a self diag...

Page 6: ...4 2 Trouble shooting If the following problems occur unlock the battery case according to section 7 in this manual and then lock it again 5 seconds later Then perform the self diagnostic test section...

Page 7: ...fter use Keep your hand and fingers behind the barriers on the probes during measurements 6 1 Voltage test double pole test Connect both probes to the object under test The voltage is indicated by LED...

Page 8: ...er test Grasp method shown as below Phase to phase voltage is indicated by each voltage LED R LED indicates that the field is rotating towards the right direction of the probe With this connection the...

Page 9: ...tes as follows when measuring continuity RX LED should be lighted and buzzer should sound continuously Note In continuity mode the instrument works in the same way as the self diagnostic test 6 4 Pen...

Page 10: ...ow and replace batteries with new ones type IEC LR03 1 5V Unlock the battery case with a coin shaped object Pull out the battery case and replace the batteries Insert new batteries according to the en...

Page 11: ...3mA battery 3V measuring 600V AC High voltage indication Voltage range 100 600V AC Phase rotation test System Three phase 4 wire system AC 50 60Hz Phase range 120 5 degrees Continuity test Detection r...

Page 12: ...Do not install the battery case without batteries Operate this unit strictly according to the manual instructions 10 Safety symbol Always check proper operation of the device on a known working circu...

Page 13: ...ng normally has two numbers 1 The first number protection against solid objects 2 The second number protection against liquids IP64 The instrument is totally protected against dust and against water s...

Page 14: ...ice 4409 Charleroi street Montreal North Quebec H1H 1T6 Telephone 514 326 7167 Fax 514 326 7835 Toll free number 1 888 326 7167 Web site www mtpinc com E mail address info mtpinc com Distributed by ww...