30
MSI-8000
Operator’s Manual
1)
Program a User Function key to
be TEST (see function key setup).
F o r t h i s e x a m p l e ,
F 1
i s
programmed as TEST.
2)
Press
F1-
TEST
.
3)
Within 2 seconds of pressing the
F1–
TEST
key, press
F1
again
(must be F1 regardless of which key is
programmed as TEST).
The test will sequence through steps 4
to 7 automatically unless you stop it by
pressing
F2
immediately. Then using
F1
and
F2
each parameter can be
observed statically.
4)
The display flashes “LFCnt” (for
Lift Counter) followed by the
number of times the weight has
exceeded 25% of capacity.
5)
Next, the display flashes “OLCnt”
(for Overload Counter) followed
by the number of times the
weight has exceeded capacity.
6)
Next,the display flashes the C-
Cal value.
7)
The Dynalink / Scale returns to
standard weighing mode. If you
interrupted the auto sequence,
press
ZERO
to return to tension
link mode.
/)&QW
2/&QW
Return to standard weight display
ENTER/SELECT
Number of Lifts above 25% of Capacity
Number of Lifts that exceeded Capacity
example value
example value
Start of Test Sequence
All segments on
&&D/
blinking
blinking
example C-Cal value
Access the Service Counters
Fx
Figure 5-8. Access the Service Counters
Only a MSI factory representative can reset the service counters, as these are an important
safety warning feature. Depending on the circumstances, a thorough load train inspection
might be necessary to ensure product safety.
Reference MSI’s “Crane Scale Safety and Periodic Maintenance Manual” for proper
loading techniques to improve the safety and longevity of your Crane Scale or Dyna-Link.
This publication is available at www.msiscales.com and is included in the CD shipped
with your
MSI-8000
.
Summary of Contents for MSI-8000
Page 1: ...MSI 8000 RF Remote Display Operator s Manual 133063 Rev C ...